Penerapan Uji Kolimator Pesawat Radiografi Stasioner Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah
DOI:
https://doi.org/10.31004/koloni.v5i3.1381Keywords:
collimator, quality control, radiation safety, radiography, X-ray beamAbstract
Quality control testing of X-ray equipment is necessary to ensure proper equipment performance and optimal diagnostic image quality. The collimator is an important component that limits the radiation field; therefore, the congruence between the light field and X-ray radiation field must be regularly evaluated. This study aimed to determine the results of collimator congruence testing on a stationary radiographic X-ray unit at the Radiology Installation of RSUP Prof. dr. I.G.N.G. Ngoerah. This quantitative study employed an observational approach, in which data were obtained through direct observation of collimator testing using a Collimator Test Tool and a Beam Alignment Test Tool. The tests evaluated the congruence between the light field and X-ray radiation field and the perpendicularity of the X-ray beam to the light field center at an FFD of 100 cm. The results showed deviations of 1.0% FFD on the X-axis and 0.6% FFD on the Y-axis, with a total deviation of 1.6% FFD. These results were within the tolerance limits of ΔX ≤ 2% FFD, ΔY ≤ 2% FFD, and ΔX + ΔY ≤ 3% FFD. The perpendicularity test showed a deviation of 1.5°, which was within the tolerance limit of ≤ 3°. Therefore, the light field and X-ray radiation field congruence and X-ray beam perpendicularity met the applicable quality control standards. The collimation system was functioning properly and supported image quality and patient radiation safety.References
BAPETEN. (2020). Peraturan Badan Pengawas Tenaga. In Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia. Retrieved from https://jdih.bapeten.go.id/unggah/dokumen/peraturan/1028-full.pdf
Bushong, S. C. (2020). Radiologic Science for Technologists: Physics, Biology, and Protection 12th Edition (12th Editi, Vol. 68). St. Louis, MO: Elsevier. Retrieved from http://www.tandfonline.com/doi/abs/10.1080/00221346908981514
IAEA. (2023). Handbook of Basic Quality Control Tests for Diagnostic Radiology. Handbook of Basic Quality Control Tests for Diagnostic Radiology, (47), 1–208. Retrieved from https://www.iaea.org/publications/14890/handbook-of-basic-quality-control-tests-for-diagnostic-radiology
ICRP. (2023). Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging. Annals of the ICRP, 52(3), 11–145. https://doi.org/10.1177/01466453231210646
Kemenkes. (2009). KMK No 1250 Tahun 2009 ttg Kendali Mutu Radiodiagnostik.pdf. Retrieved from https://id.scribd.com/document/396793191/KMK-No-1250-Tahun-2009-ttg-Kendali-Mutu-Radiodiagnostik-pdf
Lindström, J., Hulthén, M., Sandborg, M., & Tedgren, Å. C. (2020). Development and assessment of a quality assurance device for radiation field–light field congruence testing in diagnostic radiology. Journal of Medical Imaging, 7(06), 1–14. https://doi.org/10.1117/1.jmi.7.6.063501
Prasetya, A. &. (2022). Jaminan mutu pesawat ct scan. Jurnal Medika Malahayati, 6(3), 396–402. Retrieved from https://doi.org/10.33024/jmm.v6i3.8666
Zhang, J. (2025). Quality and Patient Safety in Medical Imaging. In J. Zhang (Ed.), Quality and Patient Safety in Medical Imaging. Cham: Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-89007-9
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 I Made Lana Prasetya, Kadek Krisna Bayu, Dea Ryangga

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.