Penerapan Uji Kolimator Pesawat Radiografi Stasioner Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah

Authors

  • I Made Lana Prasetya AKTEK Radiodiagnostik dan Radioterapi Bali
  • Kadek Krisna Bayu AKTEK Radiodiagnostik dan Radioterapi Bali
  • Dea Ryangga AKTEK Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.31004/koloni.v5i3.1381

Keywords:

collimator, quality control, radiation safety, radiography, X-ray beam

Abstract

Quality control testing of X-ray equipment is necessary to ensure proper equipment performance and optimal diagnostic image quality. The collimator is an important component that limits the radiation field; therefore, the congruence between the light field and X-ray radiation field must be regularly evaluated. This study aimed to determine the results of collimator congruence testing on a stationary radiographic X-ray unit at the Radiology Installation of RSUP Prof. dr. I.G.N.G. Ngoerah. This quantitative study employed an observational approach, in which data were obtained through direct observation of collimator testing using a Collimator Test Tool and a Beam Alignment Test Tool. The tests evaluated the congruence between the light field and X-ray radiation field and the perpendicularity of the X-ray beam to the light field center at an FFD of 100 cm. The results showed deviations of 1.0% FFD on the X-axis and 0.6% FFD on the Y-axis, with a total deviation of 1.6% FFD. These results were within the tolerance limits of ΔX ≤ 2% FFD, ΔY ≤ 2% FFD, and ΔX + ΔY ≤ 3% FFD. The perpendicularity test showed a deviation of 1.5°, which was within the tolerance limit of ≤ 3°. Therefore, the light field and X-ray radiation field congruence and X-ray beam perpendicularity met the applicable quality control standards. The collimation system was functioning properly and supported image quality and patient radiation safety.

References

BAPETEN. (2020). Peraturan Badan Pengawas Tenaga. In Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia. Retrieved from https://jdih.bapeten.go.id/unggah/dokumen/peraturan/1028-full.pdf

Bushong, S. C. (2020). Radiologic Science for Technologists: Physics, Biology, and Protection 12th Edition (12th Editi, Vol. 68). St. Louis, MO: Elsevier. Retrieved from http://www.tandfonline.com/doi/abs/10.1080/00221346908981514

IAEA. (2023). Handbook of Basic Quality Control Tests for Diagnostic Radiology. Handbook of Basic Quality Control Tests for Diagnostic Radiology, (47), 1–208. Retrieved from https://www.iaea.org/publications/14890/handbook-of-basic-quality-control-tests-for-diagnostic-radiology

ICRP. (2023). Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging. Annals of the ICRP, 52(3), 11–145. https://doi.org/10.1177/01466453231210646

Kemenkes. (2009). KMK No 1250 Tahun 2009 ttg Kendali Mutu Radiodiagnostik.pdf. Retrieved from https://id.scribd.com/document/396793191/KMK-No-1250-Tahun-2009-ttg-Kendali-Mutu-Radiodiagnostik-pdf

Lindström, J., Hulthén, M., Sandborg, M., & Tedgren, Å. C. (2020). Development and assessment of a quality assurance device for radiation field–light field congruence testing in diagnostic radiology. Journal of Medical Imaging, 7(06), 1–14. https://doi.org/10.1117/1.jmi.7.6.063501

Prasetya, A. &. (2022). Jaminan mutu pesawat ct scan. Jurnal Medika Malahayati, 6(3), 396–402. Retrieved from https://doi.org/10.33024/jmm.v6i3.8666

Zhang, J. (2025). Quality and Patient Safety in Medical Imaging. In J. Zhang (Ed.), Quality and Patient Safety in Medical Imaging. Cham: Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-89007-9

Downloads

Published

30-09-2026

How to Cite

Prasetya, I. M. L., Bayu, K. K., & Ryangga, D. (2026). Penerapan Uji Kolimator Pesawat Radiografi Stasioner Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah. KOLONI, 5(3), 4434–4442. https://doi.org/10.31004/koloni.v5i3.1381