Analisis Kerugian Energi pada Saluran Udara Transmisi Ekstra Tinggi 500 kv Gandul-Kembangan
DOI:
https://doi.org/10.31004/koloni.v1i4.524Abstract
Transmission lines are an important component in the distribution of electrical energy. The distance between power plants and loads depends on the length of the transmission line used. If the transmission line used is longer, the greater energy losses that occur and cause the energy reaching the loads decrease. The analysis of energy losses on the 500 kV extra high voltage transmission system from Gandul to Kembangan substation. The method is to calculate the induced voltage and induced current on the ground wire with transmission lines data using Carson Formula equation to determine the energy losses that occur on the Gandul-Kembangan 500 kV transmission lines. The results show that the energy losses are 831,2485 kW.
Keywords: Transmission, Losses, Energy
References
Praditama, Fery, Utomo, Teguh, Shidiq, M. (n.d.). Analisis Keandalan dan Nilai Ekonomis di Penyulang Pujon PT. PLN (Persero) Area Malang. 1-8
Marsudi Djiteng. (Nolki Jonal Hontong Maickel Tuegeh, dan Lily S. Patras, 2015). Operasi Sistem Tenaga Listrik. Yogyakarta. Graha Ilmu.
Sujatmiko, Hermawan. 2009. Analisis Kerugian Daya Pada Saluran Transmisi Tegangan Ekstra Tinggi 500 kV di PT. PLN (Persero) Penyaluran & Pusat Pengaturan Beban (P3B) Jawa Bali Regional Jawa Tengah & DIY Unit Pelayanan Transmisi Semarang. Jurnal Teknik Elektro. Universitas Negeri Semarang.
Syamsuri, C. Paripurna, W. Adipradana, dan Herlina, Seminar Nasional AVoER XII 2020 Palembang, 18-19 November 2020, Fakultas Teknik Universitas Sriwijaya.
Hariyadi, Shahlan. (2017). Analisis Rugi-Rugi Daya dan Jatuh Tegangan Pada Saluran Transmisi Tegangan Tinggi 150 kV pada Gardu Induk Palur – Masaran. Universitas Muhammadiyah Surakarta.
Rifai, Utomo, S.B., Haddin, M. (2019). Analisis Perhitungan Rugi-Rugi Daya Pada Saluran Transmisi Tegangan Tinggi 150 kV Gardu Induk Tambak Lorok – Bawen dengan Menggunakan ETAP 12.6.0. Konferensi Ilmiah Mahasiswa Unissula (KIMU) 2, Semarang.
O. Handayani, T. Darmana, dan C. Widyastuti. (2019). Analisis Perbandingan Efisiensi Penyaluran Listrik Antara Penghantar ACSR dan ACCC pada Sistem Transmisi 150 kV. Energi & Kelistrikan, 11(1), 37-45.
Kartika, Irine. (2017). Analisa Rugi-Rugi Daya Diakibatkan Arus Kapasitif. Jurnal Surya Energi, 1(2), 100-111.
Asman, Hari, Eteruddin, Hamzah, dan Arlenny. (2018). Analisis Proteksi Rele Jarak Pada Saluran Transmisi 150 kV Garuda Sakti – Pasir Putih Menggunakan PSCAD. SainETIn. 2(1), 27-36.
Dani, Ahmad. (2021). Analisis Rugi-Rugi Daya Pada Saluran Transmisi 150 kV Pada Gardu Induk KIM. Jurnal Indonesia Sosial Teknologi, 2(11).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Auliya Nabila

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.